Roll up doors control unit




Code CNTPR5T
230V control unit for roll up doors, programmable using a display with a scroll menu and error reporting.
Composition:
1) Control unit CNTPR5T
1) Transformer TRAXX4T
1) Radio receiver RADCN4T
1) Protective casing
SOFTWARE MANAGEMENT OF THE EXTERNAL INPUTS: It's possible to enable and disable the inputs of the control unit without having to touch the terminal block. While keeping button A or B pressed, scroll the control unit menu until visualizing the inputs parameters represented by the letter E.
E5 = STOP: it is the control parameter of the Stop input. It is a normally closed contact. During the installation of thecontrol unit, it can be useful to disable E5. If a stop switch is connected, the control unit will recognize it automatically and will enable E5 again. When the Stop input is activated the display shows ST.

E6 = PHOTOCELL: it is the control parameter of the photocell input. It is a normally closed contact. During the installation of the control unit, it can be useful to disable E6. If a photocell is connected, the control unit will recognize it automatically and will enable E6 again. When the Photocell input is activated the display shows TC.

E7 = START: It is the control parameter of the Start input. It is a normally opened contact. It is advisable to set E7 = NO if no external start device is connected. When the Start input is activated the display shows GO.

SEQUENTIAL PROGRAMMING: the sequential programming procedure allows the user to program all the roller shutter's working phases using a transmitter in a sequential mode. Each time the transmitter's button is pressed the roller shutter will start a working phase and will acquire the following programming:

1) roller shutter opens
2) roller shutter stops opening - begin of pause time during opening (the display shows a seconds countdown)
3) end of pause time - closing begins

The control unit has been completely programmed.